Surgical sutures, other suture and hemostatic materials, and brushes for surgical hand washing

Deadline:23 Jul 2026, 10:00

Tender information
Скопски
Type
Contract
Procedure
Open procedure
Estimated value
MKD 1,733,243
Duration
1 year
Surgical sutures, other suture and hemostatic materials, and brushes for surgical hand washing

Non-absorbable multifilament silk suture coated with natural wax.

Non-absorbable multifilament silk suture coated with natural wax.

Non-absorbable monofilament suture with needles having specific characteristics (tungsten-rhenium alloy) for CABG (Coronary Artery Bypass Grafting) procedures in cardiac surgery.

Non-absorbable monofilament suture with needles having specific characteristics (tungsten-rhenium alloy) for CABG (Coronary Artery Bypass Grafting) procedures in cardiac surgery.

Absorbable synthetic multifilament suture made of Polyglactin 910, impregnated with triclosan, with tensile strength retention of 75% at 14 days, 50% at 21 days, and 25% at 28 days, and a complete absorption period of 56–70 days.

Absorbable synthetic multifilament suture made of Polyglactin 910, impregnated with triclosan, with tensile strength retention of 75% at 14 days, 50% at 21 days, and 25% at 28 days, and a complete absorption period of 56–70 days.

Absorbable synthetic monofilament suture made of Polyglecaprone 25, impregnated with triclosan, with tensile strength retention of 60% at 7 days and 30% at 14 days, and an absorption period of 90–120 days.

Absorbable synthetic monofilament suture made of Polyglecaprone 25, impregnated with triclosan, with tensile strength retention of 60% at 7 days and 30% at 14 days, and an absorption period of 90–120 days.

Absorbable synthetic monofilament suture made of Polydioxanone, impregnated with triclosan, with tensile strength retention of 60–80% at 14 days, 40–70% at 28 days, and 35–60% at 42 days, and an absorption period of 182–238 days.

Absorbable synthetic monofilament suture made of Polydioxanone, impregnated with triclosan, with tensile strength retention of 60–80% at 14 days, 40–70% at 28 days, and 35–60% at 42 days, and an absorption period of 182–238 days.

Natural-origin hemostatic material made of oxidized regenerated cellulose (rayon) with a woven structure, carboxylic acid content of 19.5% w/w, pH value of less than 2.5, absorption time of 7–14 days, and bactericidal properties.

Natural-origin hemostatic material made of oxidized regenerated cellulose (rayon) with a woven structure, carboxylic acid content of 19.5% w/w, pH value of less than 2.5, absorption time of 7–14 days, and bactericidal properties.

Non-absorbable coated polyester (polyethylene terephthalate) multifilament suture composed of high molecular weight, long-chain fibers with integrated aromatic rings of linear polyester, coated and impregnated with silicone.

Non-absorbable coated polyester (polyethylene terephthalate) multifilament suture composed of high molecular weight, long-chain fibers with integrated aromatic rings of linear polyester, coated and impregnated with silicone.

Non-absorbable monofilament PTFE (polytetrafluoroethylene) undyed suture for chordae tendineae repair.

Non-absorbable monofilament PTFE (polytetrafluoroethylene) undyed suture for chordae tendineae repair.

Rectangular PTFE pledgets.

Rectangular PTFE pledgets.

Bovine pericardial patch treated with glutaraldehyde to enhance durability and prevent shrinkage and aneurysm formation. The elastic tissue adapts to the surface of application. With anti-calcification treatment that binds residual aldehydes, thereby reducing cytotoxicity and antigenicity. Dimensions: 10 × 14 cm ± 10%; thickness: 0.2–0.5 mm.

Bovine pericardial patch treated with glutaraldehyde to enhance durability and prevent shrinkage and aneurysm formation. The elastic tissue adapts to the surface of application. With anti-calcification treatment that binds residual aldehydes, thereby reducing cytotoxicity and antigenicity. Dimensions: 10 × 14 cm ± 10%; thickness: 0.2–0.5 mm.

Silicone vessel loops for organ and blood vessel retraction, made of uncoated silicone, dimensions 2 × 2.5 mm, length 45 cm, available in red, blue, and yellow colours.

Silicone vessel loops for organ and blood vessel retraction, made of uncoated silicone, dimensions 2 × 2.5 mm, length 45 cm, available in red, blue, and yellow colours.

Bone wax with a chemical composition of 70% beeswax and 30% petroleum jelly (vaseline), supplied as a 2.5 g bar.

Bone wax with a chemical composition of 70% beeswax and 30% petroleum jelly (vaseline), supplied as a 2.5 g bar.

Titanium clips for blood vessel ligation – size S (small), 3.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Titanium clips for blood vessel ligation – size S (small), 3.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Titanium clips for blood vessel ligation – size M (medium), 5.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Titanium clips for blood vessel ligation – size M (medium), 5.6 mm. The cartridge shall be adhesive and contain 9 clips. The clip shall have a pyramidal configuration with a triangular titanium profile to allow precise positioning.

Neutral electrode with an effective contact area of 85 cm² (tolerance ±10%) and a ring area of 23 cm² (tolerance ±10%), compatible with the neutral electrode connection cable for the ERBE VIO® 3 electrosurgical generator or equivalent. Intended for use in all types of surgical procedures. The electrode shall be made of a flexible material capable of adapting to any body contour and shall be suitab

Neutral electrode with an effective contact area of 85 cm² (tolerance ±10%) and a ring area of 23 cm² (tolerance ±10%), compatible with the neutral electrode connection cable for the ERBE VIO® 3 electrosurgical generator or equivalent. Intended for use in all types of surgical procedures. The electrode shall be made of a flexible material capable of adapting to any body contour and shall be suitable for use in adult patients.

Monofilament stainless steel suture wire (AISI 316L), uncoated, USP size 7, wire length 4 × 45 cm, with a 1/2-circle round-bodied sternum needle, needle length 48 mm.

Monofilament stainless steel suture wire (AISI 316L), uncoated, USP size 7, wire length 4 × 45 cm, with a 1/2-circle round-bodied sternum needle, needle length 48 mm.

Epimyocardial unipolar electrodes for adults for temporary atrial and ventricular pacing, made of stainless steel, with twisted multifilament wire insulated with polyethylene, colour-coded, wire size 2/0, wire length 60 cm, and two needles: one 1/2-circle taper-point needle, 26 mm in length, and one straight reverse-cutting break-off needle, 65 mm in length.

Epimyocardial unipolar electrodes for adults for temporary atrial and ventricular pacing, made of stainless steel, with twisted multifilament wire insulated with polyethylene, colour-coded, wire size 2/0, wire length 60 cm, and two needles: one 1/2-circle taper-point needle, 26 mm in length, and one straight reverse-cutting break-off needle, 65 mm in length.

Microsurgical knife with a rounded tip and a single sharp cutting edge, manufactured using grindless technology (without mechanical sharpening) to provide high precision and consistent blade geometry.

Microsurgical knife with a rounded tip and a single sharp cutting edge, manufactured using grindless technology (without mechanical sharpening) to provide high precision and consistent blade geometry.

Sterile single-use wound retractor with a circular ring that provides 360° circumferential retraction and maximum exposure of the surgical field through a minimal incision. The device shall provide effective wound protection by creating a physical barrier that reduces the risk of surgical site infections, prevents bacterial contamination, and helps maintain an optimal moisture environment to promo

Sterile single-use wound retractor with a circular ring that provides 360° circumferential retraction and maximum exposure of the surgical field through a minimal incision. The device shall provide effective wound protection by creating a physical barrier that reduces the risk of surgical site infections, prevents bacterial contamination, and helps maintain an optimal moisture environment to promote wound healing. The retraction shall be atraumatic, evenly distributed, and free from localized pressure, thereby minimizing additional tissue trauma and patient discomfort. The device shall enable surgical procedures without the need for an assistant to hold a manual retractor. The retraction shall provide a tamponade effect and assist in minimizing bleeding. Available sizes shall include: Small (sheath length 18 cm, incision range 2.5–6 cm) and Medium (sheath length 18 cm, incision range 5–9 cm).

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 4 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 4 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 6 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.3 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 6 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.3 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 8 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.6 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 8 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.6 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 10 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.7 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 10 mm, a graduated catheter shaft, a catheter lumen with a diameter of 1.7 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 12 mm, a graduated catheter shaft, a catheter lumen with a diameter of 2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Embolectomy catheter manufactured from biocompatible polyamide and polyurethane. The device shall consist of six components: a balloon with an inflation diameter of 12 mm, a graduated catheter shaft, a catheter lumen with a diameter of 2 mm, a Luer Lock connector, a stylet, and a Luer Lock syringe. Working length: 76 cm. Permissible dimensional tolerance: ±3%.

Automatic suture fastening system for valve surgery, consisting of at least two applicators with a minimum length of 16 cm and a diameter of 5–7 mm, and at least 12 fastening clips, suitable for open and minimally invasive surgical procedures..

Automatic suture fastening system for valve surgery, consisting of at least two applicators with a minimum length of 16 cm and a diameter of 5–7 mm, and at least 12 fastening clips, suitable for open and minimally invasive surgical procedures.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 15.2 cm × 15.2 cm × 1.65 mm.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 15.2 cm × 15.2 cm × 1.65 mm.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 2.5 cm × 15 cm × 1.65 mm.

Sterile non-woven PTFE (polytetrafluoroethylene) felt, dimensions 2.5 cm × 15 cm × 1.65 mm.

Filter for a reusable sterilization container, made of PTFE (polytetrafluoroethylene), validated for at least 1,000 cleaning and sterilization cycles, suitable for fractional vacuum and gravity displacement sterilization processes, in accordance with EN 868-2 and DIN EN 554. The filter shall have an outer diameter of Ø190 mm and shall be compatible with the JK100 filter holders on the lids of the

Filter for a reusable sterilization container, made of PTFE (polytetrafluoroethylene), validated for at least 1,000 cleaning and sterilization cycles, suitable for fractional vacuum and gravity displacement sterilization processes, in accordance with EN 868-2 and DIN EN 554. The filter shall have an outer diameter of Ø190 mm and shall be compatible with the JK100 filter holders on the lids of the existing aluminium sterilization containers used at the Clinic.

Heart stabilizer for off-pump (beating heart) cardiac surgery; low-profile design with vacuum system; two flexible stabilizers with 4 suction points each, each of which is fully bendable in all directions and adaptable to the anatomical structure of the heart and blood vessels. Suction regulation with vacuum regulator. Compatible with all retractors, with easy application and removal.

Heart stabilizer for off-pump (beating heart) cardiac surgery; low-profile design with vacuum system; two flexible stabilizers with 4 suction points each, each of which is fully bendable in all directions and adaptable to the anatomical structure of the heart and blood vessels. Suction regulation with vacuum regulator. Compatible with all retractors, with easy application and removal.

Heart positioner based on a vacuum principle, for effective positioning of the apex of the heart or left ventricle using a silicone cup; compatible with all retractors; features a 360-degree rotating head; flexible system that allows normal movement of the heart during surgery.

Heart positioner based on a vacuum principle, for effective positioning of the apex of the heart or left ventricle using a silicone cup; compatible with all retractors; features a 360-degree rotating head; flexible system that allows normal movement of the heart during surgery.

Aid for improved visualization of the surgical field, facilitates removal of blood through irrigation with a fine mist of saline solution, prevents drying and dehydration of sensitive tissue (10/box).

Aid for improved visualization of the surgical field, facilitates removal of blood through irrigation with a fine mist of saline solution, prevents drying and dehydration of sensitive tissue (10/box).

Non-absorbable polyfilament suture made of natural silk, wax-coated. Sterility, shelf life minimum 5 years. Thread thickness 1.

Non-absorbable polyfilament suture made of natural silk, wax-coated. Sterility, shelf life minimum 5 years. Thread thickness 1.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 2/0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 2/0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 3/0.

Absorbable suture (synthetic polyglycolic acid, twisted, coated, fast-absorbing type) with thread thickness 3/0.

Sterile surgical brushes for washing hands for single use, made of sponge material impregnated with disinfectant containing chlorhexidine (minimum 4%), which directly acts on Gram-positive and Gram-negative bacteria.

Sterile surgical brushes for washing hands for single use, made of sponge material impregnated with disinfectant containing chlorhexidine (minimum 4%), which directly acts on Gram-positive and Gram-negative bacteria.

Buyer
PHI UNIVERSITY CLINIC FOR CARDIOLOGY AND CARDIOVASCULAR SURGERYNATIONAL CENTER FOR CARDIOVASCULAR DISEASES
buyer-email@mail.com
organization number

Documents

Document name
Upload date
File size
First document.pdf
1 Jan 1970, 00:001 Bytes
Second document.pdf
1 Jan 1970, 00:001 Bytes
Open for offers
26 days left
Important dates
25 Jun - Publication date
23 Jul - Deadline
Unlock Full Access with Mercell Bidding Business Plus
Start your free trial to explore exclusive features that help you win more tenders, faster:
AI-Powered Tender Insights
Buyer Contact Info
Key Tender Timelines

Already have an account?

Mercell Logo

Feel free to reach out!

Mercell is the leading European provider of e-tendering and procurement systems, and information between buyers and suppliers in the professional market.

We appreciate your input.

© Mercell Group 2026

Terms & Conditions and Privacy Notice

Mercell Group

  • Email: post@mercell.com
  • Phone: +47 21 01 88 00
  • Address: Askekroken 11, 0277 Oslo, Norway

Your privacy is important to us

We use cookies to improve your experience and evaluate each item on our site. By clicking further, you accept our use of cookies.